TEL+44 (20) 8969 1367
FAX+44 (20) 8968 8913

admin@kaloricheater.co.uk
31-33 Beethoven Street
London W10 4LJ UK


:: CATALOGUE CONTENTS
compact portable
industrial fan heaters
portable fan
assisted heaters
4-20kW
unit heaters
uht unit
heaters
warm air curtains
and high level heaters
mayfair
convectors
forced air
consoles
panel
heaters
rectangular rod
type heater batteries
circular rod
type heater batteries
insertion
units
control
panels
tubular
heater units
immersion
heater units
electric
elements
ATEX, EExd
fan assisted unit
ATEX, EExd
convector heaters
ATEX, EExd cabinet
convector heaters
industrial finned
tubular heaters
halogen
heaters
ceramic
heaters
weather resistant
halogen heaters
halogen ceramic
and radiant heaters
heating
cables
heater
mats
under laminate
elements
? other products
and enquiries
   
 
   

M3 | KLH
Under Laminate Elements

APPLICATION

Ultra-thin KLH heating elements can be installed directly under laminate floors without the need for screed or adhesive. They can also be used with timber floors with a maximum thickness of 15mm*. A layer of Depron insulation placed below the KLH element will provide the necessary thermal insulation and sound deadening. In poorly insulated properties supplementary heating may be required.

* We recommend you consult your timber floor supplier to check compatability with underfloor heating.

FEATURES

Two different widths are available with standard lengths up to 10m (elements can be reduced in length on site if necessary).

Non standard lengths are available on request.

4m 'live' and 'neutral' cables are fitted

A number of elements are used to fill the floor area and are connected in parallel.

KDPT programmable thermostat with both room and floor sensor (must be ordered separately).

SELECTION

Draw a plan of the floor identifying areas occupied by fixed furniture such as kitchen cabinets (heating elements should not be installed in these areas). Draw the heating elements side by side on to the plan leaving a minimum gap of 50mm between the wall and the edge of the heating element. Whenever possible, keep the elements ends fitted with the live and neutral cables along one wall. This should be the same wall on which the thermostat is mounted.

 
Specifications

KLH4 Range
Width 400mm overall, 330mm heated
KLH5 Range
Width 530mm overall, 500mm heated
List No. Length Output List No. Length Output
m kw m kw
KLH4-010 1.0 0.04 KLH5-010 1.0 0.06
KLH4-015 1.5 0.06 KLH5-015 1.5 0.10
KLH4-020 2.0 0.09 KLH5-020 2.0 0.13
KLH4-025 2.5 0.11 KLH5-025 2.5 0.16
KLH4-030 3.0 0.13 KLH5-030 3.0 0.19
KLH4-035 3.5 0.15 KLH5-035 3.5 0.23
KLH4-040 4.0 0.17 KLH5-040 4.0 0.26
KLH4-045 4.5 0.19 KLH5-045 4.5 0.29
KLH4-050 5.0 0.21 KLH5-050 5.0 0.32
KLH4-055 5.5 0.23 KLH5-055 5.5 0.36
KLH4-060 6.0 0.26 KLH5-060 6.0 0.39
KLH4-065 6.5 0.28 KLH5-065 6.5 0.42
KLH4-070 7.0 0.30 KLH5-070 7.0 0.45
KLH4-075 7.5 0.32 KLH5-075 7.5 0.49
KLH4-080 8.0 0.34 KLH5-080 8.0 0.52
KLH4-085 8.5 0.36 KLH5-085 8.5 0.55
KLH4-090 9.0 0.39 KLH5-090 9.0 0.59
KLH4-095 9.5 0.41 KLH5-095 9.5 0.62
KLH4-100 10.0 0.43 KLH5-100 10.0 0.65

 
Depron Insulation

Dimensions (mm)
Long Wide Thick
KDEP 1200 800 6

 
Controller

Model Range Rating
KDPT +5°C to +30°C 15 amp

 

Design, specification, prices, etc. subject to alteration without notice