B1 | 4-20 kW unit heaters

KALORIC 4-20 kW Electric Unit Heaters are suitable
for industrial space heating and are available in any loading within
this range. They may be used for ventilating and cooling by fitting
a fresh air duct at the back of the heater.
The sheet steel casing, finished in Hammertone Beige, totally encloses
the fan and the open coil or rod time elements which give maximum
heat transfer to the air. The heater battery is protected against
overheating by a manual reset thermal cut-out, and this must be
wired in line with the coil circuit of a contactor. Hangers on top
of unit make installation easy and permit quick relocation when
desired.
The outlet louvres are designed to deflect the heated air with
minimum friction and are readily adjustable but remain fixed in
desired position.
Mounting bracket for wall fixing
Special wall fixing brackets are available for the whole range.
When ordering separately state loading of the Unit Heaters for which
the wall brackets are required.
Open Coil Type Unit Heaters
240V 1ph.A.C. or 415V 3ph.A.C.
Dimensions and Weights
List
No. |
Loading |
Width |
Height |
Depth |
Weight
approx. |
| kW |
in |
mm |
in |
mm |
in |
mm |
lb |
kg |
| UH.4 |
4 |
15¾ |
400 |
12½ |
318 |
22 |
559 |
26 |
11.8 |
| UH.5 |
5 |
| UH.6 |
6 |
| UH.8 |
8 |
21 |
535 |
15¾ |
400 |
25 |
635 |
44 |
19.97 |
| UH.10 |
10 |
| UH.12 |
12 |
| UH.15 |
15 |
| UH.20 |
20 |
21 |
535 |
15¾ |
400 |
25 |
635 |
44 |
20.97 |
110V 1ph.A.C.
The Unit Heaters in loadings of 3, 4 and 5 kW fitted with open
coiI type elements are also available for 1 10V 1 ph. AC. operation.
Dimensions and Weights
List
No. |
Loading |
Width |
Height |
Depth |
Weight
approx. |
| kW |
in |
mm |
in |
mm |
in |
mm |
lb |
kg |
| UH.3 |
3 |
15¾ |
400 |
12½ |
318 |
22 |
559 |
20.9 |
9.5 |
| UH.4 |
4 |
| UH.5 |
5 |
Rod Type Unit Heaters
240V 1ph.A.C. or 415V 3ph.A.C.
Dimensions and Weights
List
No. |
Loading |
Width |
Height |
Depth |
Weight
approx. |
| kW |
in |
mm |
in |
mm |
in |
mm |
lb |
kg |
| UHR4 |
4 |
15¾ |
400 |
12½ |
318 |
22 |
559 |
35.2 |
16 |
| UHR5 |
5 |
| UHR6 |
6 |
| UHR8 |
8 |
21 |
535 |
15¾ |
400 |
25 |
635 |
48 |
22 |
| UHR10 |
10 |
| UHR12 |
12 |
| UHR15 |
15 |
| UHR18 |
18 |
21 |
535 |
15¾ |
400 |
32½ |
825 |
50.6 |
23 |
| UHR20 |
20 |
When ordering state (a) Catalogue number, exact voltage and phase
of heater.
(b) Voltage and phase of fan.
Available for single and three phase A.C. supplies. Non-standard
voltages are available against special order.
These appliances must be earthed and be wired and fitted to
comply with the latest I.E.E. Regulations.
|